The AEHPC501 is used to
measure vehicle emissions of HC, CO, CO2, 02 and NOx gas concentration,
automatic calculation shows that air-fuel ratio "A, can be the engine combustion
performance and the emissions of pollution in a comprehensive test. Use of
advanced European technology and the import the key assembly components has
ensured excellence in manufacturing this state-of-the-art analyser. With features
including a high-brightness digital display, automatic zero, linear automatic
data processing, auto-alarm when the gas line is blocked, fault diagnosis where
the unit automatically calculates and prints testing date, time functions, with
built-in printer (or the analogue output interface or RS -232A digital serial
communication interface).
The AEHPC501 can freely measure idling and dual
idling and multi-mode measurement, with convenient operation, accurate
measurement data, work stable and reliable performance.
2. Main technical parameters:
Measuring range:
HC: 0~l
0000 X 10-6(ppm)vol,
CO: 0~lOX 10-2(%)vol
)
CO2: 0~20 X 10-2(%)vol, 02: 0~25 X 10-2(%)vol
NOx: 0~5000 X 1o-6(ppm)vol,
R.M.P: 0~9999r.m.p
OIL TEMP:0~150°C
Lambda: 0.50~3.00
COcor:0~10 X 10-2(%) vol
Indicating error:
HC± l 2 X 10-6(ppm)vol ( absolute error)
or±5% ( relative error)
CO±0.06 X 10-2(%)vol ( absolute error) or±5% ( relative error)
CO2±0.5 X 10-2(%)vol ( absolute error) or±5% (
relative error)
02±0.1 X 10-2(%)vol
( absolute error) or±5% ( relative error)